Enclosure 2 to SI 08 08 14 (094)

This description refers to the following chargers:

Order number Designation
81 39 0 441 922 MultiCharger 750
81 39 0 441 923 MultiCharger 900
81 39 2 161 589 MultiCharger 1500

 

Step 1: Initial situation

Before intervention in the parameter setting, the device must be disconnected from the battery or the vehicle. In addition the charging procedure on the device must be cancelled by pressing the stop button, as otherwise the parameter may be changed. Hence the operating condition 'No BL contact' must de displayed in the display.

 

Step 2: Access to device configuration

The device configuration is carried out in the service MENU. The selection is done by pressing the ENTER button. To prevent an incorrect operation, the service menu is protected by a code.

The code must be entered with the arrow buttons and confirmed with the ENTER button. The identification is '0109'.
After correct input one reaches the service menu of the multicharger.

 

Step 3: Device configuration

In the 'Adjust voltages' menu all voltage values of the multicharger can be adjusted.
In the submenu item 'Adjust charging voltage 12V' the charging voltage for battery charge is adjusted to 12V.

The following value must be entered for a lithium ion battery:

Charging voltage U = 14.0 V

In the submenu item 'Adjust charging maintenance voltage 12V' the charging maintenance voltage for battery charge is adjusted to 12V.

The following value must be entered for a lithium battery:

Maintenance voltage Uehl = 13.6 V

 

The submenu item 'Quit menu' is used to quit the 'Adjust voltage' menu.

Using the 'Store value' menu item 'Quit menu' returns to the standard display.

The charger is now ready for use on lithium batteries.